Irrigation and Melioration
Article Title
Abstract
The article justifies the necessity for the development of mobile water measuring weirsfor farmlands, a new structure of mobile weir with rectangular opening has been proposed, disadvatages of stationary water measuring weirs for temporary irrigation channels and advantages of mobile water measuring weirs is justified. Also a description of structure of mobile water measuring weir with rectangular opening is given along with schematic picture and a table for determining discharges for such weirs. Method and example for determining the sizes of weir elements, example for calculation of the amount of material needed for its individual fabrication and weir installation order has been described and conclusions are given at the end.
First Page
36
Last Page
38
References
1. Қишлоқ хўжалигида ислоҳотларни чуқурлаштиришда сувдан фойдаланувчилар уюшмасининг ўрни (Ш.Р.Хамраев тахрири остида). Тошкент, Талқин, 2009, 295 б. 2. Штеренлихт Д.В. Гидравлика. М., Энергоиздат, 1984, 640 с. 3. Практические занятия по сельскохозяйственной гидротехнической мелиорации. (под. ред. проф. Ф.М.Рахимбаева). Ташкент, “Меҳнат”, 1991, 390 с. 4. Железняков Г.В. Теоретические основы гидрометрии. Гидрометиздат. Л., 1968, 291 с.
Recommended Citation
Бакиев, М. Р. and Чориев, Ж. М.
(2016)
"КОНСТРУКЦИЯ МОБИЛЬНОГО МЕРНОГО ВОДОСЛИВА С
ПРЯМОУГОЛЬНЫМ ОТВЕРСТИЕМ И МЕТОДИКА
ОПРЕДЕЛЕНИЯ ЕГО РАЗМЕРОВ,"
Irrigation and Melioration: Vol. 2016
:
Iss.
4
, Article 10.
Available at:
https://uzjournals.edu.uz/tiiame/vol2016/iss4/10