Scientific-technical journal
Abstract
In work the calculation of humidity of helio-livestock premises during operation in different weather conditions is carried out. It is shown that the prevailing influence on the intensity of evaporation is exerted by the speed and direction of the air currents above the surface of the liquid, the temperature and humidity of the air. A program has been developed for designing a microclimate maintenance system in livestock buildings.
First Page
96
Last Page
101
Recommended Citation
Kholmirzaev, N S. and Ergashev, Sh Kh
(2019)
"CALCULATION OF MODE HELIO-LIVESTOCK PREMISES WITH PRESCRIBED HEAT ACCUMULATOR,"
Scientific-technical journal: Vol. 22
:
Iss.
2
, Article 46.
Available at:
https://uzjournals.edu.uz/ferpi/vol22/iss2/46